Production Range – Power pumps
PLUNGER pumps
TITANO | PTO/PQO/PSO | TITANO M |
- TRIPLEX (3 plungers)
- QUINTUPLEX (5 plungers)
- SEPTUPLEX (7 plungers)
Production Range – Direct acting pumps
STEAM DRIVEN pumps |
- DUPLEX (2 pistons)
- Direct acting (moved by steam)
- Double acting piston
Pump Design
- Designed and manufactured according to API 674 and ASME standards
- Guarantee a reliable service
- Reduce downtime for maintenance
- Minimize the operating cost
TITANO series – pump sizes
Series | Stroke, mm | Power, kW | No. plungers |
TITANO 3110 | 45 | up to 35 | TRIPLEX (3 plungers) |
TITANO 3120 | 70 | up to 90 | |
TITANO 3130N | 95 | up to 175 | |
TITANO 3140 | 120 | up to 265 | |
TITANO 3140Q | 120 | up to 440 | QUINTUPLEX (5 plungers) |
PTO/PQO/PSO series – pump sizes
Series | Stroke, mm | Power, kW | No. plungers |
PTO 3/160 | 175 | up to 665 | TRIPLEX (3 plungers) |
PTO 190 | 205 | up to 980 | |
PQO 190 | 205 | up to 1630 | QUINTUPLEX (5 plungers) |
PSO 190 | 205 | up to 2285 | SEPTUPLEX (7 plungers) |
Plunger Speed limitations
Depending on the fluid characteristics the plunger speed has to be limited.
Values based on Peroni experience:
FLUID | PLUNGER SPEEDS |
Lubricating and/or clean fluids (Water, oil, glycol, etc.) | < 1.3 m/s |
Volatile fluids (C02, ammonia, hydrocarbon cond. etc.) | < 1.1 m/s |
Crystallizing fluids (Carbonate, etc.) | < 0.9 m/s |
HVGO (coke slurry ) | < 0.8 m/s |
Cement ABRASIVE slurry fluids | < 0,5 m/s |